Why Is The Alarm Sounding On My Aerobic Septic System

There could be several reasons why the alarm is sounding on your aerobic septic system. It is important to address this issue promptly to prevent any potential damage or failure of the system.

Here are some possible reasons for the aerobic septic alarm sounding:

High Water Level

The alarm may be indicating that the water level in the septic tank is too high. This could be due to excessive water usage or a blockage in the system, such as a clogged filter or drain field. The alarm is a warning sign that the system is not functioning properly and needs attention.

Pump Failure

The alarm can also be triggered by a malfunctioning pump. The pump is responsible for moving the effluent from the septic tank to the drain field. If the pump fails, the alarm will sound to alert you of the issue. Pump failure can occur due to electrical problems, mechanical issues, or a clogged pump.

Power Outage

In some cases, the alarm may sound after a power outage. Aerobic septic systems rely on electricity to power various components, including the pump and the aerator. When the power is restored, the system may need to be reset to clear the alarm.

Faulty Alarm System

It is also possible that the alarm system itself is malfunctioning. This could be due to a faulty sensor, wiring issue, or other technical problems. In such cases, troubleshooting or professional assistance may be required to identify and rectify the problem.

To address the alarm sounding on your aerobic septic system, it is recommended to follow these steps:

  1. Check the water level in the septic tank and ensure it is not exceeding the recommended capacity. If it is high, reduce water usage temporarily until the issue is resolved.
  2. Inspect the pump and check for any visible signs of damage or blockage. If necessary, clean or replace the pump to restore proper functioning.
  3. Reset the system by turning off the power to the septic system, waiting for a few minutes, and then turning it back on. This may clear any temporary issues or alarms caused by power fluctuations.
  4. If the alarm persists or you are unable to identify the cause, it is advisable to contact a professional septic system service provider. They have the expertise and equipment necessary to diagnose and resolve the problem effectively.

Remember, proper maintenance and regular inspections of your aerobic septic system can help prevent alarm issues and ensure its long-term functionality.